3-56
Set the configurations with a computer
Set the configurations with a computer
Set the communication condition with the RS-232C interface and the USB identification number.Settings of
the communication conditions differ with the command (AUTO, MGL-I c1 or MGL-II c)specified using the
command change-over function.
1
Press the key in the local
mode.
2
Press the jog key or to select
[SET UP] .
3
Press the key.
4
Press the jog key or to select
[INTERFACE] .
5
Press the key.
6
Press the jog key or to select
[BAUD RATE].
Set values: 1200, 4800, 9600, 19200, 38400(bps)
7
Press the key.
8
Press the jog key or to select the following items.
The following items are provided for the setting of registration mark detection:
Data bits, Parity / Stop bits / Handshake / Step size / Close time
See pages P.3-57 for the contents of each setting item.
If you have changed the step size, be sure to raise the pinch rollers usingthe sheet set lever
and re-load the sheet on the device.