EasyManua.ls Logo

MIMAKI CJV30 Series - Page 139

MIMAKI CJV30 Series
316 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
© 2009 MIMAKI ENGINEERING CO.,LTD.
5.1.8 P.1
1
2
3
4
5
6
7
8
R.1.0
Maintenance Manual > Test Items > Test Function > [MOTOR TEST] WIPER MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
5.1.8 [MOTOR TEST] WIPER MOTOR
Function
Operation test of wiper motor is executed.
Operation Procedures
Step Item Description Remarks
1 Driving speed designation [], []: Selects driving speed of the motor.
Set value: 100 – 4000 pps (unit: 100 pps)
[], []:
Selection of item 1 – 3
2 WAIT designation [], []: Designates operation interval.
Set value: 0 – 60 sec. (unit: 1 sec.)
3 Count designation [], []: Designates No. of operation.
Set value: CONTINUE, 1 – 1000 count (unit: 1 count)
4 Test start [ENTER]: Drives the motor with designated conditions.
When CONTINUE is selected in count setting,
press [END] to finish the test.
5 End Return the wiper to the original position.