Maintenance Manual > Test Items > Test Function > [MOTOR TEST] PUMP MOTOR
Model CJV30/TPC Issued 2008.08.04 Revised F/W ver. 1.00 Remark
1.0
Rev.
5.1.9 [MOTOR TEST] PUMP MOTOR
Function
Operation test of pump motor is executed.
Operation Procedures
Step Item Description Remarks
1 Pump selection [], []: Selects pump by moving the cursor.
[], []: Selects operation.
[], []:
Selection of item 1–3
2 Rotation direction
designation
[], []: Selects pump rotation direction.
Set value: FORWARD, REVERSE
3 Driving speed designation [], []: Selects driving speed.
Set value: 1004000pps (unit: 100pps)
4 Carriage/Motor state
selection
[FUNCTION]:Carriage/motor state at test selection menu is
displayed.
<Carriage> IN: Executes at cap position.
OUT: Executes after carriage out.
<MOTOR> ON: Executes with Y-axis motor ON.
OFF: Executes with Y-axis motor OFF.
5 Test start [ENTER]: Removes the cap and moves the carriage to
maintenance position. Drives the pump motor with
designated conditions.
[END]: Ends the test.
During operation, open/
close the cartridge valve
with [FUNCTION].
6 End Test is completed.
Note that executing (FORWARD) while the cap is on causes vacuum suction.