Work procedures
1. Remove the following covers.
• Station Cover U
• C Station Cover 2
2. Remove the screws, and remove the wiper assy from the base.
3. Release the clamp under the station and disconnect the wiper
motor connector.
4. Disconnect the wiper origin sensor connector.
Be sure to turn off the main circuit breaker to prevent unexpected movements of the printer.