3.4 Nozzle check menu
This is used to check if the nozzles are clogged before printing. Sets whether to perform maintenance
functions automatically if nozzle clogging is detected.
If ≥ the set value
[Printing Check]
ON
The nozzles are not checked.
OFF
Performs nozzle recovery automatically.
Nozzle check (nozzle clogging detection)
Continue Printing
If less than the set value
[Judgment Condition] setting for nozzle clogging
detection
[Nozzle Recovery] (cleaning followed by nozzle
checking)
* Repeated by [Retry Count] cycles.
[Judgment Condition] setting for nozzle clogging
detection
Stop Printing
If ≥ the set value
[Auto Nozzle Recovery]
ON
OFF
If less than the set value
l
Menu List
Item
Setting
*1
Details
Printing Check ON/OFF Performs nozzle clogging detection before printing starts.
Check Interval - Sets the nozzle clogging detection timing.
Length 0.1 m to 30.0
m to 100.0 m
Performs nozzle clogging detection after the length set is reached
and before the next print starts.
File 1 to 30 to
1,000 files
Performs nozzle clogging detection after the preset number of files
has been printed and before the next print starts.
Action - Performs nozzle recovery (cleaning followed by nozzle checking) if
“nozzle clogging” is detected.
Cleaning Soft/Normal/
Hard
Sets the cleaning type.
Retry Count 0 to 3 times Performs nozzle recovery (cleaning followed by nozzle checking) for
the specified number of times.
Auto Nozzle
Recovery
ON/OFF Performs nozzle recovery automatically if “nozzle clogging” is
detected. See below if you wish to perform nozzle recovery
manually.
"Registering Nozzle Recovery"(P. 78)
Judgment
Condition
*2
OFF / 1 to 10
to 100
nozzles
Set the number of nozzles per row to be detected as clogged before
“nozzle clogging” is detected.
The next print will not start if “nozzle clogging” is detected during
continuous printing.
*1. The default settings are shown underlined.
*2. Nozzle recovery is not available for certain print conditions.
If an error occurs during the nozzle check operation, the next print will be automatically stopped,
and [Printing Check] will be set to "OFF". Clear the error, then set [Printing Check] to "ON"
manually.