Notes about structure and electric circuit design
1. Use non-magnetic screws, or locating pins when mounting the scanner. Magnetic screws or locating
pins can cause element/mirror central position to change.
2. It is recommended to use a thread locking method, such as a Nylok patch.
3. It is not recommended to place magnetic material (e.g. dynamic speakers, ringers, vibrators,
inductors, metal parts) within 1 inch of the scanner’s optics. Evaluate placement of all magnetic or
ferrous material during system layout to determine if 1 inch is sufficient. Please read section
“3-1
Important notes of installation”
for detail.
4. Leave sufficient space to accommodate the maximum size of the scanner.
5. Read section
“2-1 Electrical interface/Pin assignment”
carefully to learn about the electrical interface
design.
6. Read section
“2-2 Power management”
carefully to learn about the two power states.
7. Read section
“3-4 Scan angle”
carefully to learn about the scan angle of the scanner.
8. Do not hold the scanner vertically over the bar code. Please refer to section
“3-5 Tilt angle and dead
zone”
for details.
9. Refer to section
“5-13 PARAM_SEND”
, be noted that frequent permanent changes of parameter
value are not recommended due to the limited write-cycles of flash memory. It is recommended to
change parameter temporarily, if frequently modifying parameter is a must.
10. Read section
“6-4 SCI transactions notes”
carefully.