5-11 PARAM_DEFAULTS
Description: Set the parameters to default values
Packet Format
Identifies this opcode type.
Bit 0: Identifies transmit status
Bit 6-1: Unused
Bit 7: Command source
0=First time packet is sent
1= Subsequent transmission
Bit 7: always be 1(message is from the host)
All unused bits recommend to be set to 0.
0: Default setting 0 (Mindeo standard)
2's complement sum of message
contents excluding checksum.
For example: return all parameters to the factory default setting values.
Host Requirements
The host sends this command to reset the scanner’s parameter settings to the factory default values.
Scanner Requirements
Upon receiving this command, the scanner’s resets all parameters (except Scan mode) to the factory
default values. The behavior is the same as scanning factory defaults configuration barcode, see section
“11 Return default parameters & firmware version”
.