Check digit verification: The check digit verification is optional.
Check digit transmission: By setting Enable, check digit will be transmitted.
Max./Min. code length: Refer to Max./Min. code length of
“4-12 Code 39 (Code 32, Trioptic Code 39)”
.
Code ID setting: Refer to Code ID setting of
“4-7 UPC-A”
.
Insertion group selection: Refer to Insertion group selection of
“4-7 UPC-A”
.
Start/End type: Codabar has four pairs of Start/End pattern; you may select one pair to match your
application.
Start/End transmission: By setting Enable, the start and end character of a Codabar barcode will be
transmitted.
Start/End character equality: By setting Enable, the start and end character of a Codabar barcode must
be the same.