9. Fieldbus interface | 9.2 - Scale protocol | 165
9.2.5.13 Function number 112–124: transition-controlled action bits
(write)
For setting bits, see ChapterWriting bits .
As soon as the bit has been set, it is reset internally and the process is carried
out; this process is transition-controlled (for one write operation).
The bit is set as Write_Value_Select with the specified number (see
ChapterWriting bits ).
Function number 112 SetZero
Function number 113 SetTare
Function number 114 ResetTare
Function number 115 SetTest
Function number 116 ResetTest
Function number 117 ResetPwf
Function number 118 SetFixTare (function number 86, see ChapterFunc
tion number 80–92: state-controlled action bits
(write)).
Function number 119 GetFixTare (function number 87, see ChapterFunc
tion number 80–92: state-controlled action bits
(write)).
Function number 120 SetPrint
Function number 121 ResetError
Function number 122 Reserved for internal use.
Function number 123 GetDate
Function number 124 SetDate
Note: To prevent frequent writing to the EAROM, the write interval should
be no shorter than 15seconds.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Minebea Intec PR 5310/12 and is the answer not in the manual?

Minebea Intec PR 5310/12 Specifications

General IconGeneral
BrandMinebea Intec
ModelPR 5310/12
CategoryMeasuring Instruments
LanguageEnglish

Related product manuals