Noise Cancel (Continued)
CONTINUOUS AUTO NOISE CANCEL
In some instances, there may be more than one ‘quiet’
channel suitable for detecting all with similar levels of EMI
noise — you might notice this after repeating the Auto
Noise Cancel procedure multiple times, with each resulting
in a different channel being selected.
Continuous Auto Noise Cancel continuously repeats the
Auto Noise Cancel process over a longer period of time to
find the quietest channel.
Continuous Auto Noise Cancel Procedure
1. Hold the Coil stationary and away from metal.
2. Navigate to Noise Cancel:
Settings > Noise Cancel
3. Press-and-hold the Right Soft Key
(
Auto Noise Cancel) to start Continuous Auto
Noise Cancel.
An animation will appear on the screen and there will be
a series of ascending tones.
4. When the first cycle is complete (approximately
3 seconds), the selected channel will be displayed.
5. Continue to hold the Soft Key to repeat as many cycles
as desired — the channel will change if the detector
identifies a quieter channel.
Once the channel settles on a single value and the noise
levels have reduced, release the Soft Key.
MANUAL NOISE CANCEL
Setting the Noise Cancel manually allows you to listen to
each channel to select the one with the least interference.
This can be useful when detecting in close proximity to other
detectors or in locations with lots of electrical interference.
Manual Noise Cancel Procedure
1. Hold the Coil stationary and away from metal.
2. Navigate to Noise Cancel:
Settings > Noise Cancel
3. Press / to change the channel displayed on the
screen. Pause and listen to the interference being
received — Keep the detector still during this process.
4. Continue until you have chosen the channel with the
least interference.