Mini-Cam CCU210
Cleaning
To minimise down time and subsequent repairs, it is necessary to
keep your SOLOPro
+
inspection system clean. Please follow the
instructions below to help avoid disruption.
CAUTION!
Risk of fatal injuries caused by electrical current!
Ensure that no fluids can enter the control panel or penetrate the
housing of the cable reel. If this happens, immediately disconnect
the power supply and inform the Mini-Cam Service Centre.
CAUTION!
Risk of fatal injuries caused by electrical current!
For all cleaning and maintenance work disconnect the system from
the power supply.
General cleaning work
CAUTION!
High-pressure cleaners must not be used. It can cause
considerable damage to the coiler, camera and other system
components.
Cleaning agents or solvents must not be used. These can damage
the seals and other materials on the system.
Only clean water should be used.
• Clean the crawler and camera with water after the first
inspection. Only after this should you loosen electrical
connections.
• Immediately fit the protective caps after removing electrical
connections.
• Check O-rings for damage and replace if necessary and grease
regularly with O-ring lubricant.
• Clean the cable reel and control unit with a damp cloth.
• Only clean the camera and light lenses with a specific lens
cleaning cloth to prevent scratches.
21