466
Module model name read ( Page 296, Section 3.33)
B
"11043" or later
Version 1.15R
or later
Version 8.82L
or later
Module error collection function
*1 *5
( Page 297, Section 3.34)
Version 1.12N
or later
×
IP address change function
*1
( QnUCPU User's Manual
(Communication via Built-in Ethernet Port))
"11082" or later – –
Local device batch read function
*1
( Page 301, Section 3.35)
"12012" or later
Version 1.31H
or later
×
CC-Link IE Field Network ( MELSEC-Q CC-Link IE Field Network
Master/Local Module User's Manual)
Send points extension function
*5
(CC-Link IE Controller Network module)
( Page 303, Section 3.36)
"12052" or later
Version 1.40S
or later
Online change of inactive blocks (SFC)
*1
( MELSEC-Q/L/QnA
Programming Manual (SFC))
Expansion of SFC step relay points ( Page 343, Section 4.2)
Operation mode setting at SFC double block START
*1
(MELSEC-
Q/L/QnA Programming Manual (SFC))
SFC comment readout instruction
*1
( MELSEC-Q/L/QnA Programming
Manual (SFC))
–
Data up to 10238 bytes can be exchanged with the
SP.SOCSND/S(P).SOCRCV(S)/S(P).SOCRDATA instructions
*1
( QnUCPU User's Manual (Communication via Built-in Ethernet Port))
Parameter-valid drive information ( Page 42, Section 2.1.2)
–
Version 1.40S
or later
×
Program cache memory auto recovery function ( Page 251, Section
3.28)
"12122" or later
––
Extension of available index register range (Z0 to Z19) when Jn and Un are
used in the dedicated instruction ( Manuals for the network module and
the intelligent function module used)
"13022" or later
Storage of device memory error information (Memory check function)
( QCPU User's Manual (Hardware Design, Maintenance and
Inspection))
Storage of program error location (Memory check function) ( QCPU
User's Manual (Hardware Design, Maintenance and Inspection))
"13042" or later
Serial communication function
(Q03UD/Q04UDH/Q06UDH/Q10UDH/Q13UDH/Q20UDH/Q26UDHCPU)
( Page 232, Section 3.23)
"13062" or later
Version 1.62Q
or later
×
SFC control target block switching ( MELSEC-Q/L/QnA Programming
Manual (SFC))
"13102" or later
Version 1.73B
or later
×
AnS/A series compatible extension base unit
––
Communication using the A-compatible 1E frame (MC protocol) through built-
in Ethernet port ( MELSEC Communication Protocol Reference
Manual)
IP packet transfer function (CC-Link IE Field Network) ( QnUCPU
User's Manual (Communication via Built-in Ethernet Port))
*1 *5
"14022" or later
Version 1.77F
or later
×
Own station number setting function for CC-Link IE Field Network
( MELSEC-Q CC-Link IE Field Network Master/Local Module User's
Manual)
"14042" or later
Version 1.87R
or later
×
Writing/reading data to/from refresh devices with the specified station
number
*1
( MELSEC-Q/L Programming Manual (Common Instruction))
*10 – –
Function
Function
version
Serial number
(first 5 digits)
Programming tool version
GX Works2 GX Developer