467
APPENDICES
A
Appendix 2 Functions Added or Changed by Version Upgrade
High-speed interrupt function ( Page 224, Section 3.21 )
B
Version 1.98C
or later
×
Data logging function
*7
( QnUDVCPU/LCPU User's Manual (Data
Logging Function))
Version 1.98C
or later
×
IP packet transfer function (CC-Link IE Controller Network) ( QnUCPU
User's Manual (Communication via Built-in Ethernet Port))
*1 *5
"14022" or later
Version 1.98C
or later
×
Use of the file register in communication using the A-compatible 1E frame
(MC protocol) through built-in Ethernet port ( QnUCPU User's Manual
(Communication via Built-in Ethernet Port))
*1
*8
––
Expansion of routing parameter settings ( MELSEC-Q/L Programming
Manual (Common Instruction))
*1
*9
Latch clear by using the special relay and special register areas (
Page 75, Section 2.7 (4) (a))
*1
*10
Predefined protocol function ( QnUCPU User’s Manual
(Communication via Built-in Ethernet Port))
*1
"15103" or later
Version 1.501X
or later
×
Reading/writing device data from/to the CPU module on another station by
specifying an IP address ( QnUCPU User’s Manual (Communication
via Built-in Ethernet Port))
*1
"16043" or later
Version 1.513K
or later
×
Support of the iQ Sensor Solution function (data backup/restoration only) for
AnyWireASLINK and CC-Link ( iQ Sensor Solution Reference
Manual)
*1
"17012" or later 1.530C or later
Support of the iQ Sensor Solution function (data backup/restoration only) for
CC-Link IE Field Network ( iQ Sensor Solution Reference Manual)
*1
"17052" or later
×–
MELSOFT connection extended setting ( QnUCPU User’s Manual
(Communication via Built-in Ethernet Port))
*1
1.535H or later ×
CPU module data backup/restoration function ( Page 275, Section
3.32)
*1 *7
"17103" or later
Upper limit value setting for the number of backup data (CPU module data
backup/restoration function) ( Page 281, Section 3.32.1 (1))
*1
"18052" or later
Retrying the automatic backup (CPU module data backup/restoration
function) ( Page 284, Section 3.32.1 (3) (a))
*1
Support of the iQ Sensor Solution function (automatic detection of connected
device, system configuration check, communication setting reflection, sensor
parameter read/write, monitoring, and data backup/restoration) for built-in
Ethernet ( iQ Sensor Solution Reference Manual)
*1
"18072" or later 1.550Y or later
CC-Link IE Field Network Basic
*7
"18112" or later
1.555D or later ×
SLMP frame send instruction ( QnUCPU User's Manual
(Communication via Built-in Ethernet Port))
*1
––
Write-protect function for device data (from outside the CPU module) (
Page 305, Section 3.37)
*1
"19062" or later 1.566Q or later ×
Operation history function ( Page 313, Section 3.38)
*1
Simple PLC communication function ( QnUCPU User's Manual
(Communication via Built-in Ethernet Port))
*1
"20042" or later 1.575Z or later ×
Function
Function
version
Serial number
(first 5 digits)
Programming tool version
GX Works2 GX Developer