165
CHAPTER 9 PROGRAMMING
9
9.3 Program Example
Program for the common parts
If the master station does not receive a response for several link scans from the A/D converter module, it is recognized as a
cyclic transmission faulty station, resulting in the corresponding bit of the data link status of each station (SW00B0 to
SW00B7) turning on.
2. Write the programs to the CPU module of the master station, and reset the CPU module, or turn off
and on the power supply.
3. Put the CPU module of the master station into RUN.
Read Latest error code.
Turn on Error clear request flag.
Turn off Error clear request flag.
Read Latest warning code.
or Power OFF ON
RESET
RUN