242
Appendix 9 Comparison with NZ2GF2B-60AD4
Appendix 9.1 Comparison of performance specifications
The following table shows the differences in the performance specifications between the NZ2GF2BN-60AD4 and the
NZ2GF2B-60AD4.
Appendix 9.2 Functional comparison
The following table shows the differences in the functions between the NZ2GF2BN-60AD4 and the NZ2GF2B-60AD4.
Item NZ2GF2BN-60AD4 NZ2GF2B-60AD4
Accuracy
Ambient temperature (25±5) ±0.1%
±0.2%
Ambient temperature (0 to
55)
±0.2%
Conversion speed
100μs/channel
400μs/channel
1ms/channel
•400μs/channel
1ms/channel
External power supply
24VDC (20.4 to 28.8VDC)
Inrush current: 36.5A, 1ms or lower
Current consumption: 210mA
24VDC (20.4 to 28.8VDC)
Inrush current: 31.2A (for 1.5ms or shorter)
Current consumption: 230mA
Item NZ2GF2BN-60AD4 NZ2GF2B-60AD4
Conversion speed switch function
Allows switching into the following conversion
speeds:
100μs/channel
400μs/channel
1ms/channel
Allows switching into the following conversion
speeds:
•400μs/channel
1ms/channel
Speed switching of the trigger conversion function
Allows switching between 100μs/channel and
400μs/channel
Not available
Conversion speed switching of the CC-Link IE
Field Network synchronous communication
function
Allows switching between 100μs/channel and
400μs/channel
Not available
Support for extension modules
The following extension modules can be mounted:
Extension input module
Extension output module
Extension A/D converter module
Extension D/A converter module
The following extension modules can be mounted:
Extension input module
Extension output module

Table of Contents