3  SPECIFICATIONS
3.2  Performance Specifications
NZ2MFB1-32D DC input module
*1 If the input response time is set to "0ms", the actual input response time is 80s at OFF  ON, and 160s at ON  OFF.
*2 It is the noise immunity of when the input response time setting value is other than "0ms". Note that the module is easily affected by 
noise if "0ms" is set.
*3 Only one wire can be connected to a terminal of the terminal block for module power supply and FG. Multiple wires cannot be connected 
to a terminal. Connecting two or more wires may cause a poor contact.
*4 It is recommended to use the bar solderless terminal for wiring.
Item NZ2MFB1-32D
Station type Slave station
Number of input points 32 points
Rated input voltage 24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
Rated input current 6.0mA TYP. (for 24VDC)
Isolation method Photocoupler isolation
Max. number of simultaneous input points 100%
ON voltage/ON current 15VDC or more/4mA or more
OFF voltage/OFF current 5VDC or less/1.7mA or less
Input resistance 3.8k
Input response time OFFON 0ms
*1
/0.2ms/1ms/1.5ms/5ms/10ms/20ms/70ms
(Initial setting: 10ms)
ONOFF
Input type Positive common/negative common shared type
Withstand voltage 500VAC for 1 minute between all DC external terminals and the ground
Insulation resistance 10M or higher between all DC external terminals and ground (500VDC insulation resistance tester)
Noise immunity
*2
Noise voltage 500Vp-p, noise width 1s, noise frequency 25 to 60Hz (DC type noise simulator 
condition)
Protection degree IP2X
Wiring method for common 32 points/common (two points) (1-wire, screw terminal block type)
External interface Communication part RJ45 connector
Module power supply part Terminal block for module power supply and FG (Two-piece spring clamp terminal block)
I/O part 34-point one-piece terminal block
Tightening torque range for terminal screw (M3  5.2 screw): 0.59 to 0.88Nm
Applicable DIN rail TH35-7.5Fe, TH35-7.5Al (compliant with IEC 60715/JIS C 2812)
Applicable wire size For power supply Stranded wire: 0.3 to 1.5 (22 to 16 AWG), terminal slot size: 2.8mm  2.0mm
*4
For I/O Core: 0.3 to 2.0 (22 to 14 AWG)
Applicable solderless 
terminal
Terminal block for module 
power supply and FG
*3
Page 81 Applicable solderless terminal
Terminal block for input Page 84 Applicable solderless terminal
Number of occupied stations One station
Reference response time 1ms
Communication cable An Ethernet cable that meets the 100BASE-TX standard
For details, refer to the following.
 CC-Link IE Field Network Basic Reference Manual
Module power supply Voltage 24VDC (ripple rate: 5% or less) (Allowable voltage range: 20.4 to 28.8VDC)
Current 71mA or less (24VDC, all points ON)
Weight 0.30kg