EasyManua.ls Logo

Mitsubishi 00JCPU - Page 279

Mitsubishi 00JCPU
542 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
6 - 99
CHAPTER6 FUNCTIONS
1
2
3
4
5
6
7
8
6.17 Self-diagnostic Function
: Self-diagnostics is performed, : Self-diagnostics is not performed
(To the next page)
Table6.27 Self-diagnostics list (continued)
Diagnostics
Error
message
Diagnostic timing
CPU
module
status
LED status Basic
model
QCPU
High
Performance
model QCPU
Process
CPU
Redundant
CPU
RUN ERR.
Program
error
SFC step
configuration
error
CAN'T
SET(S)
Switching from STOP to
RUN
Stop Off Flashing
SFC
execution
error
SFC EXE.
ERROR
Switching from STOP to
RUN
Stop Off Flashing
SFC syntax
error
SFCP.
FORMAT
ERR.
Switching from STOP to
RUN
Stop Off Flashing
SFC
operation
check error
*1
SFCP.OPE.
ERROR
Execution of an
instruction
Stop/
Continue
Off/
On
Flashing/
On
SFC program
execution
error
SFCP.EXE.
ERROR
Switching from STOP to
RUN
Continue On On
SFC block
execution
error
BLOCK
EXE.ERRO
R
Execution of an
instruction
Stop Off Flashing
SFC step
execution
error
STEP
EXE.ERRO
R
Execution of an
instruction
Stop Off Flashing
CPU error
Watchdog
error
supervision
WDT
ERROR
Always Stop Off Flashing
Program
time-out
PRG.TIME
OVER
Always Continue On On
Redun-
dant sys-
tem error
Program,
parameter, or
DIP switch
mismatch
FILE DIFF.
Always
Power-on/reset
Mounting of tracking
cable
Backup mode change
Online change
System switching
Switching the both CPU
modules to the RUN
status
Stop Off Flashing
Operating
status or key
switch
mismatch
OPE.MODE
DIFF.
Power-on/reset
Always
Continue
/stop
Off/
on
Flashing
/on
Module
mounting
configuration
mismatch
UNIT LAY.
DIFF.
Always
Power-on/reset
Mounting of tracking
cable
Operation mode change
Stop Off Flashing
Memory card
mounting
status
mismatch
CARD
TYPE DIFF.
Power-on/reset Stop Off Flashing
Function
disable
during current
mode
CAN'T EXE.
MODE
Always Continue On On

Table of Contents

Related product manuals