1. Introduction
The α2 Series Controllers provides supervisory control for use in the home, office, factory or
wherever you need it. The
α2 Series Controllers offers flexible I/O control for varied
applications:
Applications
The
α2 Series is designed to be used for automatic applications including:
- Lighting, air-conditioning or watering control
- Opening and shutting of gates
- Security systems
- Domestic systems
- Temperature control
However, the
α2 Series Controllers is not designed to be used in the following applications:
- Applications where high reliabilities such as nuclear power control, railway facilities,
airline facilities, vehicles, combustion equipment and medical equipment are required.
- Applications in life critical situations
Please contact a Mitsubishi distributor for more information.
1.1 Special Features Display messages and Function Block data
1 ) Display messages and Function Block data
The
α2 Series can display the state of operation and the alarm on the LCD screen as a
message. The values of timers and counters can be changed in RUN mode.
- Total characters on LCD display: 12 characters x 4 lines
- Display items: Message, values (current or set) of timers and counters, analogue
values, etc.
2 ) Program Input
The user can program directly from the front panel or use the windows based
AL-PCS/WIN-E programming software Ver2.00. Pictorial representation of data is used to
connect function blocks. Please refer to the
α Software Manual.
3 ) Enhancement of clock function
The weekly and daily calendar timer function allows switch inputs that set the powerful
time dependent control capabilities.
4 ) Analog input, 0-10V/0-500
The DC input type for the
α2 Series accepts 0-10V signals with a resolution of 0-500.
5 ) High Speed Counter, max 1kHz
The
α2 Series has two dedicated high speed counters when using AL2-4EX EI1 and EI2.
6 ) High current output
Relay output is 8A/COM in the main unit AL2-14MR-*: O01-6, AL2-24MR-D: O01-04 and
the transistor output is 1A/point in the extension module.

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi AL2 Series and is the answer not in the manual?

Mitsubishi AL2 Series Specifications

General IconGeneral
ModelAL2 Series
Digital InputsYes
Digital OutputsYes
TypePLC
ManufacturerMitsubishi
Input Voltage100 to 240 VAC or 24 VDC (depending on model)
Output Voltage24V DC
Number of Inputs8 to 64 (depending on model)
Number of Outputs6 to 64 (depending on model)
Programming LanguageLadder Diagram
Communication PortsRS-232, RS-485, Ethernet (depending on model)
Operating Temperature0 to +55°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% (non-condensing)
WeightVaries depending on the model