α2
Simple Application Controllers
Function Blocks 6
6 - 11
6.5 Pulse Block
The function block emits a single pulse at any of the following user defined times:
Table 6.5: Pulse Function Block
1 ) Operation From ON to OFF
2 ) Operation From OFF to ON
3 ) Operation From ON to OFF and OFF to ON
Function Set Item Description
I Input pin for pulse operation
FB
Sends a single pulse depending on the function block conditional
setup.
Output
The function block sends a single pulse depending on the chosen
pulse operation
1) From ON to OFF
2) From OFF to ON
3) From ON to OFF and OFF to ON
000
LP
OI P
Input pin I
Output
1 operation cycle
(time to process program once)
Input pin I
Output
1 operation cycle
(time to process program once)
Input pin I
Output
1 operation cycle
(time to process program once)
2 pulse width
1 pulse width

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi AL2 Series and is the answer not in the manual?

Mitsubishi AL2 Series Specifications

General IconGeneral
ModelAL2 Series
Digital InputsYes
Digital OutputsYes
TypePLC
ManufacturerMitsubishi
Input Voltage100 to 240 VAC or 24 VDC (depending on model)
Output Voltage24V DC
Number of Inputs8 to 64 (depending on model)
Number of Outputs6 to 64 (depending on model)
Programming LanguageLadder Diagram
Communication PortsRS-232, RS-485, Ethernet (depending on model)
Operating Temperature0 to +55°C
Storage Temperature-20°C to 70°C
Humidity10% to 90% (non-condensing)
WeightVaries depending on the model

Related product manuals