Appendix 1OPERATION PROCESSING TIME
Appendix 1.4Operation Processing Time of Universal Model QCPU
Category Instruction Condition (Device)
Processing Time (µs)
Q00UJCPU Q00UCPU Q01UCPU Q02UCPU
Min. Max. Min. Max. Min. Max. Min. Max.
Basic
instruction
B *
When executed
3.700 12.100 3.700 12.100 3.700 12.100 4.000 8.200
B/
When executed
4.000 14.000 4.000 14.000 4.000 14.000 4.200 12.400
E +
Single
precision
= 0, = 0
0.420 0.300 0.240 0.180
= 2
127
, = 2
127
0.420 0.300 0.240 0.180
E +
Single
precision
= 0, = 0
0.540 0.380 0.300 0.220
= 2
127
, = 2
127
0.540 0.380 0.300 0.220
E -
Single
precision
= 0, = 0
0.420 0.300 0.240 0.180
= 2
127
, = 2
127
0.420 0.300 0.240 0.180
E -
Single
precision
= 0, = 0
0.540 0.380 0.300 0.220
= 2
127
, = 2
127
0.540 0.380 0.300 0.220
E *
Single
precision
= 0, = 0
0.420 0.300 0.240 0.180
= 2
127
, = 2
127
0.420 0.300 0.240 0.180
E/
Single
precision
= 2
127
, = 2
127
4.900 18.900 4.900 18.900 4.900 18.900 5.100 14.100
INC When executed
0.240 0.160 0.120 0.080
DINC When executed
0.240 0.160 0.120 0.080
DEC When executed
0.240 0.160 0.120 0.080
DDEC When executed
0.240 0.160 0.120 0.080
BCD When executed
0.320 0.240 0.200 0.160
DBCD When executed
0.400 0.320 0.280 0.240
BIN When executed
0.260 0.180 0.140 0.100
DBIN When executed
0.260 0.180 0.140 0.100
FLT
Single
precision
= 0
0.300 0.220 0.180 0.140
= 7FFF
H
0.300 0.220 0.180 0.140
DFLT
Single
precision
= 0
0.300 0.220 0.180 0.140
= 7FFFFFFF
H
0.300 0.220 0.180 0.140
INT
Single
precision
= 0
0.300 0.220 0.180 0.140
= 32766.5
0.300 0.220 0.180 0.140
DINT
Single
precision
= 0
0.300 0.220 0.180 0.140
= 1234567890.3
0.300 0.220 0.180 0.140
MOV ––
0.240 0.160 0.120 0.080
DMOV ––
0.240 0.160 0.120 0.080
EMOV ––
0.240 0.160 0.120 0.080
CML ––
0.240 0.160 0.120 0.080
DCML ––
0.240 0.160 0.120 0.080
BMOV
SM237
=ON
n=1
4.200 4.600 4.200 4.600 4.200 4.600 4.100 4.500
n=96
4.850 5.150 4.850 5.150 4.850 5.150 4.700 5.100
SM237
=OFF
n=1
6.800 11.300 6.800 11.300 6.800 11.300 6.300 8.900
n=96
7.450 11.900 7.450 11.900 7.450 11.900 5.900 9.500
FMOV
SM=237
=ON
n=1
4.100 4.600 4.100 4.600 4.100 4.600 4.100 4.600
n=96
4.800 5.200 4.800 5.200 4.800 5.200 4.800 5.200
SM237
=OFF
n=1
4.600 8.250 4.600 8.250 4.600 8.250 4.600 7.900
n=96
6.150 10.600 6.150 10.600 6.150 10.600 5.300 8.500
XCH ––
2.250 8.100 2.250 8.100 2.250 8.100 2.500 6.000
DXCH ––
2.400 8.200 2.400 8.200 2.400 8.200 2.800 7.900
DFMOV
SM237
=ON
n=1
2.700 2.800 2.700 2.800 2.700 2.800 2.350 2.450
n=96
6.500 6.800 6.500 6.800 6.500 6.800 5.950 6.000
SM237
=OFF
n=1
4.000 8.150 4.000 8.150 4.000 8.150 3.000 6.950
n=96
8.000 12.200 8.000 12.200 8.000 12.200 6.600 10.600
S1
S2
D
S1
S2
D
S
D
S
D
S
D
S1
S2
D
S1
S2
S1
S2
S
D
S
D
S
D
S1
S2
D
S1
S2
S1
S2
S1
S2
D
S1
S2
S1
S2
S1
S2
D
S1
S2
S
S
S
S
S
S
S
S

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Mitsubishi MELSEC-Q/L and is the answer not in the manual?

Mitsubishi MELSEC-Q/L Specifications

General IconGeneral
BrandMitsubishi
ModelMELSEC-Q/L
CategoryController
LanguageEnglish

Related product manuals