25
4Specication
No. 99MBE011A
4
Specication
4.1
Specications
Item Specication
Eective length (L
0
)
100, 150, 200, 250, 300, 350, 400, 450, 500, 600, 700, 750, 800,
900, 1000, 1100, 1200, 1300, 1400, 1500 mm
Scale reference point
50-mm pitch, center point, left edge point, or right edge point (de-
termined when shipped)
Indication accuracy (20 °C)
(3 + 3L
0
/1000) µm
(When L
0
≦ 500 mm, a high precision type with (2+2L
0
/1000) µm
can also be produced.)
L
0
: Eective length (mm)
Vibration resistance (55 Hz—
2000 Hz)
200 m/s
2
* Only for xing at multiple points
Shock resistance (1/2 sin, 11
ms)
250 m/s
2
* Only for xing at multiple points
Air supply Available * Only for xing at multiple points
Output signal
Type
PA/PA, PB/PB, PZ/PZ
Electrical
specication
Compliance with RS422
Main scale grid pitch 20 µm
Minimum resolution 0.1, 0.2, 0.5, 1, 2.5, 5 µm (xed when shipped)
Minimum edge interval 125, 250, 333, 500, 1000 ns (xed when shipped)
Maximum response speed
5.4 m/min—120 m/min
(Determined based on minimum resolution and minimum edge
interval)
Power supply voltage 5 VDC ±5 %
Maximum current consumption 200 mA
Sliding force 5 N or less
Used temperature range 0 °C—45 °C
Storage temperature range -20 °C—70 °C
Used/storage humidity range 20 %—80 % RH (non condensation)
Direction switch Forward/reverse (set when shipped)
Alarm function
Alarm detec-
tion
Over speed, scale signal error
Alarm output
High impedance for all PA/PA, PB/PB, and PZ/PZ output
Alarm indica-
tion
Steady red LED on signal cable NC connector (D-sub connector)
* Except for one detector cable type (without connector)