Parameter Setup List
Reference Display
Notation in
the manual
Setup content
Default
(Factory defaults)
3.2.1
”unit”
(Only for inch spec)
Switching the unit system
between inch and mm
“in”
(Only for inch
spec)
3.2.2
“res.”
Switching the digital
resolution
mm spec: 0.0005
Inch spec: 0.00002
3.2.3
“range” Switching the analog range
mm spec: 0.01
Inch spec: 0.0004
3.2.4
“dir”
Switching the count
direction
“ ”
No display: +
direction
3.2.5
“output”
Switching the I/O format
between SPC and RS232
SPC
(Digimatic)
3.2.6
“id”
Setting ID No. for RS232
communication remote
control
00
3.2.7
“start”
Switching the length
measuring system between
INC and preset systems.
INC
3.2.8
“reset”
Returning parameters to
defaults.
3.2.1
3.2.2
Switching the unit system between inch and mm during display of “unit”
(only in inch spec)
1 Put the instrument in the Parameter Setup mode, and then quickly press and release
the [MODE] key repeatedly until “unit” on the LCD starts blinking.
2 Quickly pressing the [SET/ZERO] key changes “unit” from blinking to lighting-up and
blinks the currently-set unit system.
3 Press the [MODE] key quickly to switch to a desired unit (in or mm).
4 Quickly press the [SET/ZERO] key to apply the setting and switch the setup item to
the next “res.”.
Switching the digital resolution during display of “res.”
1 Put the instrument in the Parameter Setup mode, and then quickly press and release
the [MODE] key repeatedly until “res.” on the LCD starts blinking.
2 Press the [SET/ZERO] key quickly to blink the currently-set digital resolution.
3 Press the [MODE] key quickly to switch the setting to a desired resolution.
Unit system Selectable resolution
mm 0.0005mm 0.001mm
inch (only for inch spec)
.00002” .00005” .0001”
4 Quickly press the [SET/ZERO] key to apply the setting and switch the setup item to
the next “range”.
IMPORTANT
Upon switchover of the current unit system or digital resolution, this instrument
automatically makes conversions of the preset values and tolerance limit values. After
changing such a parameter, be sure to check the converted values.
No. 99MAH016B