EMC INDUSTRIAL GROUP LTD Keys
MW93A_IM_ALL_SV6.09f_en 58/59
Icon Description
The setting is locked. Password must be entered to edit.
The setting can only be viewed.
The setting has been changed from the default.
The setting is being edited.
Use numbered keys to change setting value.
Use UP & DOWN keys to scroll through selection list.
Use UP & DOWN keys to turn setting on or off.
Use the arrow keys to move through the bits of a control or status register.
Actions
start key
Press this key to start the system. If the system is running, pressing this key will pause the system.
stop key
Press this key to stop the system.
pause key
Press this key to pause or unpause the system.
stop2 key
This key may be customised for a particular application.
toggle volumetric mode
Press this key to put the controller into volumetric mode. In volumetric mode, the required speed de-
mand is estimated from the flowrate setpoint. When the volumetric icon is displayed, the speed demand
has been set manually, and no longer does it increase or decrease with the flowrate setpoint.
print
Press the PRINT key to produce a Status Report printout.
print total
Press this key to print the totalised weight.
reset total weight
Press this key to reset the totalised weight.
acquire zero
Press this key to zero the weight display.
toggle remote mode
Press this key to select the remote flowrate setpoint. Press the key again to use the local flowrate set-
point.
user function 1
This key may be customised for a particular application.
user function 2
This key may be customised for a particular application.
user function 3
This key may be customised for a particular application.
Settings
batch setpoint
Press this key to display the BATCH WEIGHT setting. Use the keypad to set the batch weight.
speed demand
Press this key to display the SPEED DEMAND setting. If the speed demand is set using the keypad, the
controller is automatically put into volumetric mode.
flow
Press this key to display the LOCAL FLOWRATE setting. Use the keypad to set the local flowrate set-
point.
Alarm menu
An alarm is indicated by a flashing alarm icon. An alarm number will flash in the display while a fault is
active or until it is acknowledged.

Table of Contents

Related product manuals