EasyManuals Logo

Moog Matriarch User Manual

Moog Matriarch
77 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #62 background imageLoading...
Page #62 background image
64
(Continued)
Global Parameters
Group 1
Group Select
Key
Parameter
Select Key
Sync Enable
Button Blinks
1.5 MIDI Clock Input C#2 A#0 1 x / 5 x
The Matriarch Sequencer and Arpeggiator can be set to follow MIDI Clock, and can respond to Start and Stop
commands received via MIDI. Depending on your setup, you may wish for Matriarch to ignore some of these
commands. Use the first three white keys to select FOLLOW MIDI CLOCK + MIDI START/STOP COMMANDS (C0),
FOLLOW MIDI CLOCK ONLY (Ignore MIDI Start/Stop commands) (D0), or IGNORE ALL MIDI CLOCK + MIDI
START/STOP COMMANDS (E0). The Default is FOLLOW MIDI CLOCK + MIDI START/STOP COMMANDS.
1.6 MIDI Clock Output C#2 C#1 1 x / 6 x
The Matriarch Sequencer and Arpeggiator can be set to output MIDI Clock, as well as MIDI Start and Stop
commands. Depending on your setup, you may wish for Matriarch to not send some of these commands. Use
the first three white keys to select SEND MIDI CLOCK + MIDI START/STOP COMMANDS (C0), SEND MIDI
CLOCK ONLY (Do not send MIDI Start/Stop commands) (D0), or DO NOT SEND MIDI CLOCK + MIDI START/
STOP COMMANDS (E0). The Default is SEND MIDI CLOCK + MIDI START/STOP COMMANDS.
1.7 Local Control (Keyboard) C#2 D#1 1 x / 7 x
The Matriarch Keyboard, Pitch, and Modulation wheels can be disconnected from the internal synth engine,
while still outputting MIDI and CV/Gate data. Use the lowest two white keys to select Local Control (Keyboard)
OFF (C0), or ON (D0). The Default is ON.
1.8 Local Control (Arp / Seq) C#2 F#1 1 x / 8 x
The Matriarch Arp / Sequencer module can be disconnected from the internal synth engine while still
outputting MIDI and CV/Gate data. Use the lowest two white keys to select Local Control (Arp / Seq) OFF
(C0), or ON (D0). The Default is ON.
1.9 Receive Program Change C#2 G#1 1 x / 9 x
MIDI Program Change commands (Program Numbers 1 through 12) can be used to load a previously saved
Matriarch sequence, and make it the active sequence. Turning this Global Setting OFF will prevent errant
Program Change commands from inadvertently activating a saved sequence. Use the lowest two white keys
to select OFF (C0), or ON (D0). The Default is ON.
1.10 Send Program Change C#2 A#1 1 x / 10 x
Matriarch can be set to send a MIDI Program Change command (Program Numbers 1 through 12) when the
OCT / BANK switch and SEQUENCE knob on the front panel are used to select and load a previously saved
sequence from memory. Turning this Global Setting OFF will prevent Program Change commands from being sent
when a sequence is selected. Use the lowest two white keys to select OFF (C0), or ON (D0). The Default is OFF.

Other manuals for Moog Matriarch

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Moog Matriarch and is the answer not in the manual?

Moog Matriarch Specifications

General IconGeneral
Product typeAnalog synthesizer
Sound effectsDelay
Sound effects quantity1
Keyboard number of keys49
Maximum polyphony (notes)4
MIDI inYes
6.35 mm (1⁄4-inch) input3
6.35 mm (1⁄4-inch) output2
Input voltage240 V
DC input voltage12 V
Power source typeDC
AC input frequency50 - 60 Hz
Weight and Dimensions IconWeight and Dimensions
Depth361 mm
Width810 mm
Height139 mm
Weight13610 g