5 Mounting
40 BA6820378-03 EN
5.4.1 Attaching the lifting gear
NOTICE
Damage to the dehydrating breather
The device can become damaged or fall if it is set down vertically on the air
exhaust.
Do not support or set the device down on the air exhaust.
To mount the dehydrating breather on the counter-flange, proceed as fol-
lows:
1. Lift and upright the DB200D / DB200G with the help of a second person.
Each person should have one hand on the air exhaust and one hand on
the connection pipe.
Figure20: Lifting and uprighting the DB200D / DB200G