Operation 2-6DXL5000 User and Technical Manual
in a standard 19-inch (48.3 cm) rack. The cabling is permanently
installed and power comes from the facility or site power source.
Each installation will have its own specific tasks according to the
application and the installed hardware options.
For installation information, refer to the “Installation” section on
page 4-1.
2.3.2 Powering the DXL5000 System Transmitter
CAUTION
Corruption of software contained in the
DXL5000 System Transmitter may occur if
proper power down or power up of the
DXL5000 does not occur.
The software will become corrupted and the
DXL5000 System Transmitter may have to
be returned to the factory for repair.
The DXL5000 System Transmitter must be properly powered up
and powered down to prevent possible corruption of the software
contained in the radio. It will take approximately 30 seconds for
the DXL5000 System Transmitter to initialize.
Power to the DXL5000 System Transmitter must never be cycled
off and on without a minimum delay of 10 seconds between
removal of power and application of power.
Conversely, power to the DXL5000 System Transmitter must
never be cycled to on and then immediately to off, as corruption
of software contained in the radio may also occur.
Power Up
The steps required to properly power up the DXL5000 System
Transmitter are contained in the following steps.
CAUTION
If power is accidentally lost, do not
immediately re-apply power to the DXL5000
System Transmitter.
Internal software corruption may occur if
power is applied immediately after a power
loss.
To avoid possible software corruption, wait a
minimum of 10 seconds before re-applying
power.
Note
If you are unsure of the power requirements or
connections to the DXL5000 System Transmitter,
refer to the “Installation” section on page 4-1 .
Note
When the DXL5000 System Transmitter is
powered up, it will automatically return to the last
settings that were in use when the unit was
powered down.
The unit will also resume transmitting if the unit
was transmitting when it was powered down, as
long as there are no alarms preventing
transmitting.
1. Verify the power cable is properly connected to the
DXL5000 System Transmitter rear panel AC POWER
IN connector.

Table of Contents