Installation 4-11DXL5000 User and Technical Manual
Table 4-5: CHAN1 and CHAN2 T1/E1 Connector Pin-Outs
4.8.6 WAYSIDE DATA Connections
The WAYSIDE DATA DB-9 male connector provides RS-232
connections for SCM operations. For pin-outs, see Table 4-6.
Connector
Information
Pin
CHAN1
Signal
Description
CHAN2
Signal
Description
RJ-45 Connector. 1 E1CH0_OUT_
N
E1CH1_OUT_
N
2 E1CH0_OUT_
P
E1CH1_OUT_
P
3 NC NC
4 E1CH0_IN_N E1CH1_IN_N
5 E1CH0_IN_P E1CH1_IN_P
6 N/C N/C
7 N/C N/C
8 N/C N/C
1 2 3 4 5 6 7 8
4.8.7 CHAN1 and CHAN2 DATA Connections
CHAN1 and CHAN2 DATA RJ-45 connectors provides 10/100
Base T Ethernet connections to the unit. For pin-outs, see
Table 4-7
on page 4-12.
Table 4-6: WAYSIDE DATA Connections
Connector
Information
Pin
Signal
Description
(Transmitter)
Signal
Description
(Receiver)
9-Pin, Male, “D”
Connector.
1 NC NC
2 SCM_RS232_
RX
N/C
3 N/C SCM_RS232_
TX
4 N/C N/C
5 N/C N/C
6 N/C N/C
7 RS485_SIG- RS485_SIG-
8 RS485_SIG+ RS485_SIG+
9 N/C N/C
1
5
6
9