GB
Maintenance and Care MSA
46 AirGo
(4) Slide on protective cap as follows:
Push both operating buttons simultaneously and slide on protective cap
until it audibly and visibly snaps into place on the snap-on hooks.
(5) Assemble handwheel as follows:
For AutoMaXX-AE and AuroMaXX-N only
Push in safety clamp and simultaneously push and hold down both
operating buttons.
Slide on handwheel until stopper.
Attention!
Observe the right seat of positive pressure spring in the guide of the
diaphragm.
Fig. 32 Handwheel assembly
For further information please observe the separate Operation Manual
for the AutoMaXX System (Part No. 10083261).