The entries in the NTP peers table have the following format:
OBJECTNUMBER
Name
Access
Type
Description
1
staNtpRemote
AddressType
read-only
enum
Type of IP address of the remote
NTP server:
0 unknown
1 ipv4
2 ipv6
3 ip4z
4 ip6z
16 dns
2
staNtpRemote
Address
read-only
string
IP address of the remote NTP
server
3
staNtpLocal
AddressType
read-only
Enum
Type of IP address of the local
NTP client:
0 unknown
1 ipv4
2 ipv6
3 ip4z
4 ip6z
16 dns
4
staNtpLocal
Address
read-only
String
IP address of the local NTP client
5
StaNtpStratum
read-only
Integer
Stratum of the remote NTP
server
6
staNtpPoll
read-only
Integer
Frequency of server polling in
seconds
7
staNtpReach
read-only
Octal
Octal bitmask of success or
failure of last 8 queries (left-
shifted). e.g:
377 11111111 all 8 recent
queries were successful
317 11001111 from 8 recent
queries 5
th
and 6
th
failed
8
staNtpDelay
read-only
String
Network round trip time in
seconds
9
staNtpOffset
read-only
String
Difference between local clock
and remote server’s clock in
seconds
10
staNtpDispersion
read-only
String
Maximum error of the local
clock relative to the reference
clock in seconds
11
staNtpFlag
read-only
String
NTP flag