SECTION 106: Sensor Signals
X
X
SECTION 107: Emergency Stop
An Astragal Swing Door Unit can be operated in a single Door Panel mode. An acve EMY-IN signal on the Slave programs the closing
sequence as a single Door Panel conguraon. If only the EMY-IN signal on the Master is acve, then this EMY-IN signal is applicable for
both Door Panels. In accordance with the acon congured on the Master by means of EMY-IN, both Door Panels carry out a CL-SPR
(Close Spring), STOP, OPEN or CL-MOT (Close Motor).
If only the EMY-IN signal on the Slave is acve, then the Slave carries out a CL-SPR, regardless of the acon congured on the Slave by
means of EMY-IN. If both EMY-IN signals are acve, then the Master performs its congured EMY-IN acon and the Slave performs a
CL-SPR. One excepon of this rule is the Master in the EMY-IN conguraon OPEN. In this case, both Door Panels will be opened.
Note: The respecve control and safety sensor are connected to the corresponding drive unit.
1. Plug both ends of (1) CAN Cable into each (Socket X117) located on each GT20 Control, to connect both Operator Assemblies.
2. Go to the Master GT20 Control. Select the Parameter EMY-IN. Select the Seng Range: Open
3. Go to the Slave GT20 Control. Select the Parameter EMY-IN. Select the Seng Range: Open
4. Go to the Master GT20 Control. Select the following parameters:
X DubleD = MastA
X AcSeq = desired me lag of the closing angle.
5. Go to the Slave GT20 Control. Select the following parameters:
X DubleD = SlaveA
X AoSeq = desired me lag of the opening angle.
SECTION 108: Check Connecons
Note: A small white (m) and a small white (s) indicates: a missing connecon.
1. Check the LCD Display on the Master GT20 Control to see if a small black (m) is visible on the rst level (connecon exisng).
2. Check LCD Display on the Slave GT20 Control to see if a small black (s) must be visible on the rst level (connecon exisng).
3. Transmit a Key (open) command to the Slave control by applying a Jumper to Terminals 2 & 3.
a. The Master will be is the rst one to open, followed by the Slave.
b. In the open posion the hold-open me expires on the display of the Slave control.
c. The Slave is rst to close, followed by the Master.
SECTION 109: Interlock Operaon
Note: Both Operator Assemblies must be running o the same power circuit.
1. Plug both ends of (1) CAN Cable into each (Socket X117) located on each GT20 Control, to connect both Operator Assemblies.
2. Program both GT20 Controls for standard open speed, close speed, etc. as required.
3. For the Exterior Door Panel (A), select the Parameter: InterL, Select the Seng Range: SideA
4. For the Interior Door Panel (B), select the Parameter: InterL, Select the Seng Range: Side B
Side A
Side B
Interior side
Exterior side
DN 1184
Figure 6