SECTION 106: Sensor Signals
X 
X 
SECTION 107: Emergency Stop
An Astragal Swing Door Unit can be operated in a single Door Panel mode. An acve EMY-IN signal on the Slave programs the closing
sequence as a single Door Panel conguraon. If only the EMY-IN signal on the Master is acve, then this EMY-IN signal is applicable for
both Door Panels. In accordance with the acon congured on the Master by means of EMY-IN, both Door Panels carry out a CL-SPR
(Close Spring), STOP, OPEN or CL-MOT (Close Motor).
If only the EMY-IN signal on the Slave is acve, then the Slave carries out a CL-SPR, regardless of the acon congured on the Slave by
means of EMY-IN. If both EMY-IN signals are acve, then the Master performs its congured EMY-IN acon and the Slave performs a
CL-SPR. One excepon of this rule is the Master in the EMY-IN conguraon OPEN. In this case, both Door Panels will be opened.
Note:  The respecve control and safety sensor are connected to the corresponding drive unit.
1. Plug both ends of (1) CAN Cable into each (Socket X117) located on each GT20 Control, to connect both Operator Assemblies.
2. Go to the Master GT20 Control. Select the Parameter EMY-IN. Select the Seng Range: Open
3. Go to the Slave GT20 Control. Select the Parameter EMY-IN. Select the Seng Range: Open
4. Go to the Master GT20 Control. Select the following parameters:
  X DubleD = MastA
  X AcSeq = desired me lag of the closing angle.
5. Go to the Slave GT20 Control. Select the following parameters:
  X DubleD = SlaveA
  X AoSeq = desired me lag of the opening angle.
SECTION 108: Check Connecons
Note:  A small white (m) and a small white (s) indicates: a missing connecon.
1. Check the LCD Display on the Master GT20 Control to see if a small black (m) is visible on the rst level (connecon exisng).
2. Check LCD Display on the Slave GT20 Control to see if a small black (s) must be visible on the rst level (connecon exisng).
3. Transmit a Key (open) command to the Slave control by applying a Jumper to Terminals 2 & 3.
a. The Master will be is the rst one to open, followed by the Slave.
b. In the open posion the hold-open me expires on the display of the Slave control.
c. The Slave is rst to close, followed by the Master.
SECTION 109: Interlock Operaon
Note:  Both Operator Assemblies must be running o the same power circuit.
1. Plug both ends of (1) CAN Cable into each (Socket X117) located on each GT20 Control, to connect both Operator Assemblies.
2. Program both GT20 Controls for standard open speed, close speed, etc. as required.
3. For the Exterior Door Panel (A), select the Parameter: InterL, Select the Seng Range: SideA
4. For the Interior Door Panel (B), select the Parameter: InterL, Select the Seng Range: Side B
Side A
Side B
Interior side
Exterior side
DN 1184
Figure 6 

Other manuals for Nabco GT20

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Nabco GT20 and is the answer not in the manual?

Nabco GT20 Specifications

General IconGeneral
BrandNabco
ModelGT20
CategoryDoor Opening System
LanguageEnglish

Related product manuals