29 of 43
www.NabcoEntrances.com GT20 Wire and Programming Manual
Rev 5-7-18 P/N C-00140
Element
Unit Type Default Value Description
Inverse Full & Low OFF OFF...ON In the event of a power failure/error, the Door Panel is opened by spring power
from any posion (unless it has been locked). The posion of the motor connector
is reversed with regard to the standard drive unit.
Teach must be acvated aer this seng has been changed.
dAxis Full & Low 7in 2...25IN Distance between center line of the door hinges and the mounng surface of the
Operang Assembly. dAxis is an approximate value. Depending on the installaon
situaon, dAxis may have to be esmated.
Teach must be acvated aer this seng has been changed.
Table 11
Element
Default Value Description
APuGO OFF OFF,
2°...10°
Triggering angle for Push&Go (angle push&go).
ASES 95° 45°...95° Lock out angle:
X Angle at which swing side door mounted sensor is ignored just before open.
X If Ao is changed, ASES is auomacally set to Ao.
ASER 0° 0°...60° Lock out angle:
Angle at which push side door mounted sensor is ignored just before closing.
inac ve
DN 1188
closed
ASES
closed
SES
SER inac ve
Element
Default Value Description
SESClo INACTIVE ACTIVE Sensor mounted on Swing side of Door Panel is acvated or inacvated during closing cycle.
INACTIVE
EMY-IN CL-SPR Conguraon of the Emergency terminal (break contact) (emergency input)
CL-SPR Spring Close (Standard Applicaon)
STOP Stops Door Panel Closing/Opening
OPEN Opens Door Panel
CL-MOT Motor Close (Inverse Applicaon)
OExSTp OFF OFF N/A X Used to set one of the acvaon "Values" to
“sequenal” mode.
X Sequenal mode is used to hold the door open unl a second
acvaon is received.
X One acvaon opens the Door Panel and a second acvaon is
required to close the Door Panel.
OEI Opening
Element Inside
OEO Opening
Element Outside
KEY Opening
Element NIGHT
RADIO N/A
UNLOCK PERMAN IMPULS When the Door Panel is rst open: Momentarily unlocks Electric Lock.
PERMAN When the Door Panel is rst open: Permanently unlocks Electric Lock.
EL-Fb OFF OFF Electric Lock status feedback.
N.O. Open if unlocked (-); Closed if locked (+)
N.C. Open if locked (+); Closed if unlocked (-)