Element
Unit Type Default Value Description
Inverse Full & Low OFF OFF...ON In the event of a power failure/error, the Door Panel is opened by spring power
from any posion (unless it has been locked). The posion of the motor connector
is reversed with regard to the standard drive unit.
Teach must be acvated aer this seng has been changed.
dAxis Full & Low 7in 2...25IN Distance between center line of the door hinges and the mounng surface of the
Operang Assembly. dAxis is an approximate value. Depending on the installaon
situaon, dAxis may have to be esmated.
Teach must be acvated aer this seng has been changed.
Table 11 
Element
Default Value Description
APuGO OFF OFF,
2°...10°
Triggering angle for Push&Go (angle push&go).
ASES 95° 45°...95° Lock out angle:
X Angle at which swing side door mounted sensor is ignored just before open.
X If Ao is changed, ASES is auomacally set to Ao.
ASER 0°...60° Lock out angle:
Angle at which push side door mounted sensor is ignored just before closing.
inac ve
DN 1188
closed
ASES
closed
SES
open
ASER
SER inac ve
Element
Default Value Description
SESClo INACTIVE ACTIVE Sensor mounted on Swing side of Door Panel is acvated or inacvated during closing cycle.
INACTIVE
EMY-IN CL-SPR Conguraon of the Emergency terminal (break contact) (emergency input)
CL-SPR Spring Close (Standard Applicaon)
STOP Stops Door Panel Closing/Opening
OPEN Opens Door Panel
CL-MOT Motor Close (Inverse Applicaon)
OExSTp OFF OFF N/A X Used to set one of the acvaon "Values" to
“sequenal” mode.
X Sequenal mode is used to hold the door open unl a second
acvaon is received.
X One acvaon opens the Door Panel and a second acvaon is
required to close the Door Panel.
OEI Opening
Element Inside
OEO Opening
Element Outside
KEY Opening
Element NIGHT
RADIO N/A
UNLOCK PERMAN IMPULS When the Door Panel is rst open: Momentarily unlocks Electric Lock.
PERMAN When the Door Panel is rst open: Permanently unlocks Electric Lock.
EL-Fb OFF OFF Electric Lock status feedback.
N.O. Open if unlocked (-); Closed if locked (+)
N.C. Open if locked (+); Closed if unlocked (-)