25
Display Zones Bypassed? Displays bypassed zones. If needed, press NEXT
(P) and PRIOR (Q) to scroll bypassed zones.
Display Zone Directory? Displays a listing of all zones in the Area. If needed, press
NEXT (P) and PRIOR (Q) to scroll zone directory.
Activate Siren Test? Activates the alarm sounder (while disarmed) for about 2
seconds and performs a battery test. If the alarm does not sound, call for service.
• If the battery is low, a “LOW BATTERY E02-00 SERVICE” will appear in the display
indicating a low battery condition. Allow 24 hours for the battery to recharge. If the
trouble continues, call for service.
Display Fire Alarms? Displays alarms that have occurred on the Fire Zone(s). Press
the NEXT and PRIOR buttons to scroll zones.
Display Fire Troubles? Displays trouble conditions that have been detected on the
Fire Zone(s). Use NEXT (P) and PRIOR (Q) to scroll zones.
Activate Chime? The Chime Mode will sound a tone at the keypad when the
programmed zone is faulted while disarmed. To deactivate the Chime Mode, re-enter
the Keypad Menu Mode and when “DEACTIVATE CHIME“ is displayed, press YES
(P). Note: The Chime Mode is disabled while armed.
KEYPAD MENU MODE
ACTIVATE
SIREN TEST Y/N
DISPLAY
FIRE ALARM Y/N
DISPLAY
FIRE TRBL Y/N
ACTIVATE
CHIME Y/N
DISPLAY
ZN BYPASSED Y/N
DISPLAY
ZN DIRECTORY Y/N