6
general information
1.1 rates and effi ciencies
Natural Gas Propane
Min. Inlet Gas Supply
Pressure
4.5" w.c. (11mb) 11" w.c. (27mb) 4.5" w.c. (11mb) 11" w.c. (27mb)
Max. Inlet Gas Supply
Pressure
7"* w.c. (17mb) 13” w.c. (32mb) 13” w.c. (32mb) 13” w.c. (32mb).
Manifold Pressure (Under
Flow Conditions)
3.5” w.c. (9mb) 10” w.c. (25mb) 3.5 w.c. (9mb) 10” w.c. (25mb)
TLV50 / TLV62 / TLV74
TLV50
Appliance Type
TLV50N TLV50P
Fuel Type
Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 36,000 31,500
Min. Input (BTU/HR) 25,000
TLV62
Appliance Type
TLV62N TLV62P
Fuel Type
Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 44,000 38,000
Min. Input (BTU/HR) 29,000 28,000
TLV74
Appliance Type
TLV74N TLV74P
Fuel Type
Natural Gas Propane
Altitude (FT) 0-4,500
Max. Input (BTU/HR) 48,000 41,500
Min. Input (BTU/HR) 30,000 33,000