EasyManua.ls Logo

NEC BladeServer Express5800 Series - Page 122

NEC BladeServer Express5800 Series
292 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Loading...
Configuring Your Server 4-65
Parameters for VD Definition
Listed below are parameters for Configuration Wizard.
Item Parameter Remarks
RAID Level RAID 0 / RAID 1 / RAID 5
Strip Size 8 KB / 16 KB / 32 KB / 64 KB / 128 KB Recommended value: 64KB
Access Policy RW / Read Only / Blocked Recommended value: RW
Read Policy Normal / Ahead / Adaptive Recommended value: Normal
Write Policy WBack / WThru / BadBBU WBack: WriteBack
WThru: WriteThru
BadBBU: Unavailble
IO Policy Direct / Cached Recommended value: Direct
Disk Cache Policy Unchanged / Enable / Disable Recommended value: Unchanged
Disable BGI No / Yes Specify whether to perform
Background Initialize after creation
of VD.
Recommended value: No
IMPORTANT:
BGI (Back Ground Initialize) is available only for
RAID5 VD configured with five or more HDDs.