4-30
recovered by using the auto rebuild feature. The hard disk drive to be used as a standby disk must have the
same capacity and the same rotational speed as those of the other hard disk drives.
The following 5 types of hard disk status are displayed by MegaRAID Configuration Utility. Each status is
explained below:
[READY] Not yet configured.
[ONLIN] The disk is turned on and ready for normal operation. Configured into a pack.
[HOTSP] The disk is on and in Hot spare disk status.
[FAIL] Judged to be faulty by the controller. Cannot be used.
[REBLD] Being rebuilt.
Starting Configuration Utility
MegaRAID Configuration Utility is stored in the BIOS of RAID controller on I/O board and started during POST
activation.
Starting MegaRAID Configuration Utility
Check that the following is displayed when you turn the power on your server
The manufacturer’s logo
The message “ Press <F2> to enter Setup, <F4> Service Partition, <F12> Network”
Then press Esc, POST screen is displayed.
Check that the following is displayed in the POST screen, then press
Enter.
NOTE: When Ctrl + H is blinking onscreen, do not press Ctrl + H. If you press these keys,
WebBIOS starts after POST is completed. When WebBIOS is started, click [Control-M] at
the upper right of the screen to start MegaRAID Configuration Utility.