8-18
Error
code
Error message Recommended Action
0615 COM B configuration changed.
0616 COM B config. error - device disabled.
0617 Floppy configuration changed.
0618 Floppy config. error - device disabled.
0619 Parallel port configuration changed.
061A Parallel port config. error - device disabled.
0B00 Rebooted during BIOS boot at Post Code.
0B1B PCI System Error on Bus/Device/Function.
0B1C PCI Parity Error on Bus/Device/Function.
Contact your service representative.
0B28
Unsupported Processor detected on
Processor 1.
0B29
Unsupported Processor detected on
Processor 2.
0B2A
Unsupported Processor detected on
Processor 3.
0B2B
Unsupported Processor detected on
Processor 4.
Make sure that the server supports the processor. If you are
not sure, contact your service representative to request the
maintenance.
0B30 Fan 1 Alarm occurred.
0B31 Fan 2 Alarm occurred.
0B32 Fan 3 Alarm occurred.
0B33 Fan 4 Alarm occurred.
0B34 Fan 5 Alarm occurred.
0B35 Fan 6 Alarm occurred.
0B36 Fan 7 Alarm occurred.
0B37 Fan 8 Alarm occurred.
A fan failure or fan clogging may occur. Contact your service
representative to request the maintenance.
0B50 Processor #1 with error taken off line.
0B51 Processor #2 with error taken offline.
0B52 Processor #3 with error taken offline.
0B53 Processor #4 with error taken offline.
The processor is degraded. Contact your service
representative.
0B5F Forced to use Processor with error
Because an error is detected in every processor, the system is
forcibly started. Contact your service representative.
0B60 DIMM group #1 has been disabled
0B61 DIMM group #2 has been disabled
0B62 DIMM group #3 has been disabled
0B63 DIMM group #4 has been disabled
0B64 DIMM group #5 has been disabled
0B65 DIMM group #6 has been disabled
0B66 DIMM group #7 has been disabled
0B67 DIMM group #8 has been disabled
0B70
The error occurred during temperature sensor
reading.
Contact your service representative.
0B71 System Temperature out of the range.
A fan failure or fan clogging may occur. Contact your service
representative to request the maintenance.
0B74
The error occurred during voltage sensor
reading.
0B75 System voltage out of the range.
0B78 The error occurred during fan sensor reading
Contact your service representative.
0B7C
The error occurred during redundant power
module confirmation
Contact you service representative to replace the power supply
unit.
0B7D
The normal operation can't be guaranteed
with use of only one PSU
Contact you service representative to add an additional power
supply unit or replace the existing power supply unit.