3-9
To connect the power cord from the server to an uninterruptible power supply (UPS), use service outlets on the rear of
the
The UPS service o
"O d "OUTPUT2".)
To
to
Fo
per
<E
UPS.
utlets are categorized into two groups: SWITCH OUT and UN-SWITCH OUT. (They may be called
UTPUT1" an
control power supply with an application (ESMPRO UPS Controller) that controls the UPS, connect the power cord
a SWITCH OUT outlet.
r constant power supply, connect the power cord to an UN-SWITCH OUT outlet. (Plug a modem that has a
manent connection to this outlet.)
xample>
2
OUTPUT
(UNSWITCH OUT)
OUTPUT(SWITCH OUT)
AC100V 50/50HZ
UN-SWITCH OUT SWITCH OUT
When the power cord is connected from the server to a UPS, change the BIOS setup of the server link with power
supply from the UPS.
Change a parameter for "AC-LINK" und
to
er the Server menu of the BIOS setup utility. See Chapter 4 for details.