InMail System Guide 1 - 1
Chapter
1
Quick Setup
SECTION 1 INSTALL THE VM8000 INMAIL BLADE
1. Take adequate anti-static precautions.
N
Wear a grounded wrist strap at all times when installing or
removing the VM8000 InMail blade.
N
Ensure the wrist strap is attached to a known earth ground
(such as the earth ground lug on the CHS2U-US).
N
Discharge any built-up static electricity by touching the cabinet
earth ground lug.
2. Install four plastic stand-offs included with the VM8000 InMail blade
before installing the CompactFlash card assembly.
N
Locate stand-offs as shown in Figure 1-1 CPU without InMail
Daughter Board (PZ-VM21) and CompactFlash on page 1-2.
N
Be sure to install the stand-offs from the back (underneath)
side of the blade.
3. Install the VM8000 InMail CompactFlash card assembly face up as shown
in Figure 1-2 InMail Daughter Board with CompactFlash Card Assembly
Installed on page 1-2.
4. Insert the VM8000 InMail blade into the CN4 connector on the CPU.
N
Position the VM8000 InMail blade over the CN4 connector —
then push the blade into the connector on the CPU.
The InMail CompactFlash drive must never be inserted or removed
with the chassis power on. Always turn chassis power OFF when
inserting or removing the InMail CompactFlash drive.