VM8000 Issue 1.0
InMail System Guide 2 - 175
14-05-01 Trunk Groups
Assign trunks to trunk groups (1~8).
By default, all trunks are in group 1.
14-06-01 Trunk Group Routing
Set up Trunk Group Routing. There are 8 routing tables, with 4 routes in
each table.
By default, the first route in routing table 1 is trunk group 1. No other entries are
defined. This makes trunk group 1 the dial 9 route by default.
Refer to Trunk Group Routing in the SV8100 Programming Manual for
more.
2. Set the maximum number on incomplete callout attempts.
47-01-14 Number of Callout Attempts (Notify Call Attmpt)
Set how many times (1~99 attempts) VM8000 InMail retries an incomplete
Message Notification callout. This total includes unacknowledged callouts,
callouts to a busy destination, and callouts to an unanswered destination.
This option applies to pager and non-pager callouts.
The default setting for this option is 5 attempts.
3. Be sure Message Waiting lamp for Subscriber Mailboxes is on.
47-02-08 Message Waiting Lamp (Update MW Lamp)
Enter 1 (Yes) to enable Message Waiting lamp.
If Message Waiting lamp is disabled (0), Message Notification will not
function.
By default, this option is 1 (Yes).
Unique Programming for Non-Pager Message Notification
1. Set the intervals VM8000 InMail waits between incomplete non-pager Message
Notification callouts.
47-01-10 Wait Between Non-Pager Callout Attempts (Notify N-Pgr Intvl)
Set the minimum time (1~255 minutes) between non-pager Message
Notification callouts in which the destination answers, says “Hello,” dials 1
to acknowledge and then enters the wrong security code.
The default for this option is 20 minutes.
47-01-11 Wait Between Busy Non-Pager Callout Attempts (Notify Busy Intvl)
Set how long VM8000 InMail will wait (1~255 minutes), after it dials a busy
non-pager callout destination, before retrying the callout number.
The default for this option is 15 minutes.