Issue 1.0 VM8000
3 - 16 Programming
H
Announcement Messages.
H
Call Routing Mailbox Instruction Menus.
The length of a Conversation Record is 10 times the Subscriber Message
Length. Since the Conversation Record time cannot exceed 4095 seconds, any
settings in Subscriber Message Length larger than 409 has no effect on the
length of recorded conversations.
See the following for more:
N
Announcement Message on page 2-23
N
Automated Attendant on page 2-45
N
Routing Mailbox on page 2-211
N
Live Record on page 2-139
N
Greeting on page 2-109
N
Subscriber Mailbox on page 2-227
Options
1~4095 seconds
Default
120 seconds
47-01-04 Non-Subscriber Message Length (Mbox Msg Length)
Use this option to set the maximum length of recorded messages for:
H
Automated Attendant callers leaving a message or Quick Message in a
Subscriber Mailbox.
H
Outside callers transferred by an extension user to a Subscriber Mailbox.
See the following for more:
N
Automated Attendant on page 2-45
N
Message Length on page 2-169
N
Quick Message on page 2-203
N
Subscriber Mailbox on page 2-227
Options
1~4095 seconds.
Default
120 seconds.
47-01-05 Message Backup/Go Ahead Time (Msg Bkup/Adv Time)
Use this option to set the backup/go ahead interval. This interval sets how
far VM8000 InMail backs up when a user dials B while listening to a
message. This interval also sets how far VM8000 InMail jumps ahead when
a user dials G while listening to a message.
See the following for more:
N
Listening to Messages on page 2-135
N
Message Length on page 2-169