VM8000 Issue 1.0
InMail System Guide 2 - 33
Programming
1. Assign Answer Tables to trunks.
47-10-01 Answer Table Assignment (Answer Table)
Assign an Answer Table (1~8) to each trunk that the Automated Attendant
should answer.
By default, all trunks are assigned to Answer Table 1.
2. Set up the Automated Attendant to answer trunk calls.
22-02-01 Incoming Call Trunk Setup
Assign Service Type 4 to each trunk you want to be a DIL. Make a separate
entry for each Night Service mode.
By default, trunks are Service Type 0 (Normal).
22-07-01 DIL Assignment
For each trunk you designated above, enter the VM8000 InMail pilot
number. Make a separate entry for each Night Service mode.
By default, there are no DIL destinations programmed.
3. Select the Answer Table you want to customize.
47-11 VM8000 InMail Answer Table Options
Select the Answer Table you want to customize (1~8).
47-11-04 Next Answer Table (Next Answer Table)
If 10 Answer Schedules in an Answer Table are not sufficient, enter the
number of the Answer Table to which you want to link the selected table.
VM8000 InMail treats the two linked tables as a single 20 entry Answer
Table.
By default, Answer Tables are not linked.
47-11-03 Default Mailbox Category (Default MB Ctg) and 47-11-03 Default
Mailbox Number (Default MB Num)
Set the mailbox the Answer Table will use if no Answer Schedule is in
effect.
By default, this option is Call Routing Mailbox 1 for Answer Table 1 and 0
(undefined) for all other Answer Tables.
4. Setting up a Type 1 (Day of Week) schedule.
47-12 VM8000 InMail Answer Schedules
Select the Schedule Entry you want to customize.