17
© by NECTA VENDING SOLUTIONS SpA 07-2002 148 03
Coin mechanism
The machine is locked if it receives a pulse longer than 2
seconds on a validator line or the communication with the
serial coin mechanism does not take place for more than
30 seconds (Executive protocol) or 75 seconds (BDV
protocol).
RAM Data
One or more areas of the RAM contain wrong data which
was corrected with the default values.
The machine will continue to function, but it would be
advisable to initialise as soon as possible.
Machine control board
Failed dialogue between C.P.U. board and machine con-
trol board.
Fresh-brew unit 1
Due to wrong positioning of the unit (piston opening time
> 8 seconds). The machine is not locked, but all fresh
product based selections are disabled.
Fresh-brew scraper 1
Wrong positioning of the waste ejection scraper (move-
ment time > 6 seconds).
The machine is not locked, but all fresh product based
selections are disabled.
Fresh-brew unit 2 / Fresh-brew scraper 2
As unit and scraper 1 if the second Brewer unit is installed.
RESETTING
By confirming this function all current failures will be reset
PROGRAMMING PARAMETERS
CASH
This set of functions controls all parameters regarding the
payment systems and the sales prices.
SELECTION PRICES
Four different prices can be set for each selection accord-
ing to the programmed time bands for when the time table
option is enabled.
For each of the 4 time bands prices (0 to 65,535) can be
programmed globally (same price for all selections) or for
the single selections.
Should the majority of products be sold at the same price,
it will be convenient to set the price globally and then
change the figure of the selections with different prices.
Time bands
Four programmable time bands are provided for selling
products at different prices.
The time periods are programmable for beginning and end
time by hours (00 to 23) and minutes (00 to 59).
If the values for start and end of the time band are set to
00.00 the time period is disabled.
The reference time is kept by an internal clock, program-
mable as:
day/month/year week-day 1-7
and then
hour/minutes/seconds.
If the values for start and end of the time band are set to
00.00 the time period is disabled.
COIN MECHANISMS
It is possible to decide which of the payment system
protocols available are to be enabled for the functions.
The available payment systems are:
- Validators
- Executive
- BDV
- MDB
By selecting one of the systems it is possible to control
its functions.
Validators
When the “Validat. Lines” (line setting) function of the
“Technician” menu is displayed, the value of the 6 validator
coin lines can be changed.
Executive
The following payments systems are available for the
Executive system:
- Standard
- Price Holding
- Coges
- U-Key
- Sida