© by NECTA VENDING SOLUTIONS SpA
16
07-2002 148 03
Statistics Display Selection
counters
Counters by
time bands
Discount counters
Failure counters
Coin mechanisms
Cancel Partial
Total
Relative displaySelection
counters
Counters by
time bands
Discount counters
Failure counters
Coin mechanisms
Cancel relative Partial
Total
Display counter at start-up
Print Partial
Relative print Partial
Total
Test Complete selection
Unit control Enable
provisionally
buttons A÷I.
Autotest Actuation in
a sequence of:
.doser devices
.mixers
.cup dispenser
.stirrer dispenser
.neon lamps
.door LED
.push-buttons
.mobile spouts
.coffee dose
.unit rotation
.waste cont. switch
Miscellaneous Machine info. installation date
Machine codes
Operator code
Initialising
GSM Pin Code setting the code
for the modem
Pre-alarms set threshold
reset counters
FAILURES
READING PRESENT FAILURES
When the “Failure” function is displayed, press the con-
firm button “
” to display the present failures.
If no failures are currently present, after pressing the
confirm button “ ” the message “End failures” will be
displayed.
The possible failures are indicated in the following cases:
Water failure
If the air-break microswitch is closed for more than one
minute, the water inlet solenoid valve will remain ener-
gized until the water flow is restored.
Instant boiler
The machine is locked if after 20 minutes of heating time
from machine start or from the last selection, the instant
boiler fails to reach the operating temperature.
Espresso boiler
The machine is locked if after 10 minutes of heating time
from machine start or from the last selection, the coffee
boiler fails to reach the operating temperature (Only if the
espresso unit is fitted).
Mobile spouts
If the spouts do not reach the dispensing position, the
machine is disabled.
No cups
When the empty cup column microswitch opens, the
column shift motor is activated. If after one full turn of the
cup dispenser the microswitch is not closed the machine
locks.
Espresso unit 1
This failure is due to a mechanical lock of the unit or when
the unit is not present. The machine is not locked, but all
coffee-based selections are disabled (Only if the es-
presso unit is fitted).
Coffee failure 1
If after a period of 15 seconds of grinding coffee a dose is
not obtained, all coffee-based selections are disabled
(Only if the espresso unit is fitted).
Espresso unit 2 / Coffee failure 2
As Espresso unit 1 and Coffee failure 1 if the second coffee
unit is fitted.
Coffee release
If after releasing the ground coffee dose the microswitch
of the coffee doser unit indicates the presence of coffee
in the dosing chamber, all coffee-based selections are
disabled (Only if the espresso unit is fitted).
Volumetric counter
Failed computation of the volumetric counter within a max.
given time (Only if the espresso unit is fitted).
Waste container full
This occurs after the liquid waste container float is
triggered.
Air-break
The machine is locked if after 7 selections the microswitch
has never signalled the lack of water.