EasyManuals Logo

Necta Zenith Fresh Brew Instant User Manual

Necta Zenith Fresh Brew Instant
80 pages
To Next Page IconTo Next Page
To Next Page IconTo Next Page
To Previous Page IconTo Previous Page
To Previous Page IconTo Previous Page
Page #29 background imageLoading...
Page #29 background image
25
© by NECTA VENDING SOLUTIONS SpA 07-2002 148 03
PROGRAMMER SETUP READING SETUP 01 <X>
SETUP READING SETUP 01 <X> Confirm?
SETUP READING
SETUP 20 <X>
PROGRAMMER CREATE SETUP SETUP 01 <X>
CREATE SETUP SETUP 01 <X> Confirm?
CREATE SETUP
SETUP 20 <X>
TRANSFERRED DATA
The following data is transferred with the setup:
. Water and powder doses
. Price table
. Prices and selections status
. Basic coin
. Decimal point
. Value of validator lines
. BDV / MDB data
. N. of “Jug Facilities” selections
CONFIGURING THE LANGUAGE
It is possible to change the programmer configuration
regarding the language in which the messages are to be
displayed as well as to reset all of the data therein
contained.
To activate the “Programmer configuration” mode do as
follows:
- insert the programmer in its holder and start the machine.
- wait for about 10” and then press programmer keys “C” and
“O”; the first function will be thus displayed:
CONFIGURATION CONFIGURATION CONFIGURATION
LANGUAGE ITALIAN Confirm?
CONFIGURATION
FRENCH
CONFIGURATION
GERMAN
CONFIGURATION
ENGLISH
CONFIGURATION
SPANISH
CONFIGURATION INITIALISING
INITIALISING Confirm?
CONFIGURATION
CONFIG. END Exit from the configuration menu
The software restarts from address 0000
(as at machine start-up)
The integrity of the machine and compliance with the
standards of the relevant systems must be checked at
least once a year by qualified personnel.
Before starting any maintenance operations requiring
parts of the unit to be removed, the machine must
always be switched off.
The operations described below must be carried out
only by personnel who have the specific knowledge of
the machine functioning from a point of view of electrical
safety and health regulations.
INTRODUCTION
To ensure correct operation for a long period, the machine
must be subjected to regular maintenance.
The following sections contain the procedures and the
maintenance schedule, which are only a general indication,
as they greatly depend on the operating conditions (e.g.
water hardness, environmental humidity and temperature,
type of product used, etc.).
The procedures described in this chapter are not exhaus-
tive of all maintenance operations to be carried out.
More complex operations (e.g. boiler descaling) should be
carried out by qualified technicians only having specific
knowledge of the machine.
To prevent oxidation or the action of chemical agents, the
stainless steel and varnished surfaces should be kept
clean by using mild detergents (solvents must not be used).
Never use water jets to clean the machine.
BREWER UNIT MAINTENANCE
As well as cleaning once a week and/or every 2,500
selections, the brewer filter and its seal must be replaced
every 25,000 selections, even if they appear to be still
efficient.
The brewing unit must be disassembled completely and
its components thoroughly cleaned every 100,000 selec-
tions replacing all worn out parts.
The brewing cylinder must be changed even if it appears
to be still sound and efficient.
During these operations the area beneath the brewing
chamber is to be properly cleaned.
Important notice!!
Should the whole unit need to be removed, do not handle
it by the cylinder or by the filter holder.
Chapter 3
MAINTENANCE

Table of Contents

Questions and Answers:

Question and Answer IconNeed help?

Do you have a question about the Necta Zenith Fresh Brew Instant and is the answer not in the manual?

Necta Zenith Fresh Brew Instant Specifications

General IconGeneral
BrandNecta
ModelZenith Fresh Brew Instant
CategoryVending machines
LanguageEnglish

Related product manuals