3x230 V
Output data according to EN 14 511
2.18kWSpecified heating output (P
H
)
1
3.93COP
1
2.03kWSpecified heating output (P
H
)
2
3.24COP
2
1.88kWSpecified heating output (P
H
)
3
2.74COP
3
Additional power
10.0 (factory setting 6.67)kWOutput immersion heater
Electrical data
230 V 3N~50 HzVRated voltage
See table page 24AMax operating current
15-55WDriving power circulation pump
25-140WDriving power exhaust air fan
See table page 24AFuse
IP 21Enclosure class
Refrigerant circuit
R290, propaneType of refrigerant
0.4kgVolume
2.45/24.5MPa/barCut-out value pressostat HP
0.15/1.5MPa/barCut-out value pressostat LP
Heating medium circuit
0.25/2.5MPa/barMax pressure in boiler section
70 (factory setting 60)°CMax temperature (flow line)
Ventilation
28l/sMin. air flow at exhaust air temperature at least 20 °C
31l/sMin. air flow at exhaust air temperature below 20 °C
Sound effect level according to EN 12 102
46.5-48.0dB(A)Sound power level (L
W(A)
)
4
Sound pressure levels
42.5-44.0dB(A)Sound pressure level in the boiler room (L
P(A)
)
5
Pipe connections
22mmHeating medium ext Ø
22mmHot water ext Ø
22mmCold water ext Ø
22mmDocking ext Ø
125mmVentilation Ø
NIBE™ F370Chapter 12 | Technical data66