affect hot water
Here you set whether the temperature of the hot water
should be affected when activating "SG Ready".
With low price mode on "SG Ready" the stop temper-
ature of the hot water is set as high as possible at only
compressor operation (immersion heater not permit-
ted).
With over capacity mode of "SG Ready" the hot water
is set to "luxury" (immersion heater permitted).
affect cooling (accessories required)
Here you set whether room temperature during cooling
operation should be affected when activating "SG
Ready".
With low price mode of "SG Ready" and cooling oper-
ation the indoor temperature is not affected.
With over capacity mode of "SG Ready" and cooling
operation the parallel offset for the indoor temperature
is reduced by"-1". If a room sensor is installed and ac-
tivated, the desired room temperature decreases by 1
°C.
affect pool temperature (accessories required)
Here you set whether pool temperature should be af-
fected when activating "SG Ready".
With low price mode of "SG Ready" the desired pool
temperature (start and stop temperature) is increased
by 1 °C.
With over capacity mode of "SG Ready" the desired
pool temperature (start and stop temperature) is in-
creased by 2 °C.
NOTE
The function must be connected to two AUX
inputs and activated in menu 5.4.
Menu 4.2 - op. mode
op. mode
Setting range: auto, manual, add. heat only
Default value: auto
functions
Setting range: compressor, addition, heating, cooling
The indoor module operating mode is usually set to
"auto". It is also possible to set the indoor module to
"add. heat only", but only when an addition is used, or
"manual" the select yourself what functions are to be
permitted.
Change the operating mode by marking the desired
mode and pressing the OK button. When an operating
mode is selected it shows what in the indoor module
is permitted (crossed out = not permitted) and select-
able alternatives to the right. To select selectable
functions that are permitted or not you mark the
function using the control knob and press the OK but-
ton.
Operating mode auto
In this operating mode the indoor module automatic-
ally selects what functions are permitted.
Operating mode manual
In this operating mode you can select what functions
are permitted. You cannot deselect "compressor" in
manual mode.
Operating mode add. heat only
In this operating mode the compressor is not active
and only additional heating is used.
Caution
If you choose mode "add. heat only" the com-
pressor is deselected and there is a higher op-
erating cost.
Caution
You cannot change from only additional heat
if you do not have a slave connected (see
Menu 5.2.2).
Functions
"compressor" is that which produces heating and hot
water for the accommodation. If "compressor" is
deselected, a symbol in the main menu on the symbol
for the indoor module. You cannot deselect "com-
pressor" in manual mode.
"addition" is what helps the compressor to heat the
accommodation and/or the hot water when it cannot
manage the whole requirement alone.
"heating" means that you get heat in the accommod-
ation. You can deselect the function when you do not
wish to have heating running.
"cooling" means that you get cooling in the accommod-
ation in hot weather. You can deselect the function
when you do not wish to have the cooling running.
This alternative requires an accessory for cooling or if
the heat pump has a built in function for cooling and
is activated in the menu.
Menu 4.3 - my icons
You can select what icon should be visible when the
door to VVM 310 is closed. You can select up to 3 icons.
If you select more, the ones you selected first will disap-
pear. The icons are displayed in the order you selected
them.
Menu 4.4 - time & date
Set time and date, display mode and time zone here.
TIP
Time and date are set automatically if the heat
pump is connected to NIBE Uplink™. To obtain
the correct time, the time zone must be set.
Menu 4.6 - language
Choose the language that you want the information
to be displayed in here.