30 – ENGLISH
TECHNICAL SPECIFICATIONS
Description Technical specication
HO7124 HO7224
Radio receiver
OXI (version with antenna connector
mounted)
-
Programmable functions
8 ON-OFF functions and 8 adjustable
functions (see “Level 1 programming
(ON-OFF)” paragraph)
-
Self-learning functions
Self-learning of the devices connected to
the BlueBus output
Self-learning of the type of “STOP” device
(Normally Open, Normally Closed contact
or 8.2 kΩ resistor)
Self-learning of the gate path and
automatic calculation of the slowdown
and partial opening points.
Self-learning of the operation with one or
two motors.
-
Assembly
Vertical, with a dedicated xing plate
Operating temperature
-20°C ÷ 55°C(at low temperatures, the gearmotor’s efciency decreases)
Use in highly acid, saline or potentially
explosive atmosphere
No
Protection rating
IP 54 (with container intact)
Dimensions and weight
180x252xh290h
Weight
9 kg 6,5 kg
* Frequency of cycles at the maximum temperature: 25 cycles/hour
** Maximum continuous cycle time at the maximum temperature: 8 minutes
*** The “Warning light” and “Electric lock” outputs can be programmed with other functions (see paragraph “Level 1 program-
ming (ON-OFF)“), or paragraph “Connecting the Oview programmer“). The electrical characteristics of the outputs can
be adapted on the basis of the type of chosen function: warning light function: 12 Vc, 21 W max lamp; electric lock function:
12 Va, 15 VA max; other outputs (all types): 1 lamp or relay 24 Vc (–30 e +50%), 4 W max.