5.10 Menus 18,19 - Application Parameters
These two menus are designated as application parameters since they are all free to be
used for whatever purpose the user wants.
Both menus are identical in their layout. All parameters are read/write access to the
Second Processor (and via comms), but may be read-only on the drive’s keypad.
This parameter is automatically saved by the drive on power-down.
Pr
1x.11-Pr 1x.50 are saveable in the drive’s non-volatile memory.
Pr 1x.01 Integer, read-write saved on power-down
Access RW Range Signed 16-bit
Default 0 Update Rate N/A
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer
Pr 1x.02-
Pr 1x.10
Integer, read-only
Access RW (RO drive) Range Signed 16-bit
Default 0 Update Rate N/A
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer
Pr 1x.11-
Pr 1x.30
Integer, read-write
Access RW Range Signed 16-bit
Default 0 Update Rate N/A
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer
Pr 1x.31-
Pr 1x.50
Bit, read-write
Access RO Range 0/1
Default 0 Update Rate N/A
Apps Apps Lite Apps Plus Lite V2 ST Plus ST Indexer