System Setup
3-3
Part 1604857-04
E 2014 Nordson Corporation
System Connections
System Diagram
WARNING: This diagram does not show all system grounds. All conductive
equipment in the spray area must be connected to a true earth ground.
NOTE: The input air filter shown in this diagram is mounted behind the
front panel of mobile systems. For rail- or wall-mount systems, the filter and
mounting bracket are shipped in a kit for mounting at the customer’s plant.
Purge Air
Power
Supply
AC Power Cord
Fluidizing Air
Manifold
24VDC
Air Wash Air
Atomizing Air
Flow-Rate Air
Gun cable
6mm black
4mm clear
8mm blue
8mm black
6mm blue
Spray Gun
Powder hose
6mm blue*
Pickup Tube
VIibrator Motor*
Pump
Input Air
10mm
Filter
VBF Power Cord*
6mm black
Conductive*
Encore LT
Controller
Main Control Board
Keypad
* VBF System
** Hopper System
Dolly or Booth
Ground
6mm blue**
Feed
Hopper**
Powder Box*
Relay
Board
Line
Filter
Sol. & Regulator Wiring
10mm