System Setup
3-16
Part 1604857-04
E 2014 Nordson Corporation
Controller Configuration
Power Up Sequence
When power is applied to the system, the controller goes through the
following sequence:
1. All displays and LEDs light for 3 seconds.
2. The main control board configuration is displayed on the KV/A panel:
A: Auto (refer to troubleshooting to change the jumper if A is displayed)
H: Manual
3. The controller software and hardware version are displayed on the
KV/A panel in the form N.NN for 1 second.
NOTE: If the spray gun is triggered on during power-up or wake up from
disable, the trigger LED blinks at a fast rate. Release the trigger and repeat
the sleep/wake up cycle.
Entering Configuration Mode
To enter configuration mode, press and hold the Plus and Minus buttons on
the kV/uA panel while either turning on power or pressing the
Enable/Disable button (if the controller is already powered up). After 1
second all panels flash CF for 3 seconds. After 3 seconds the kV/
A panel
displays F − 1 for function 1. The controller is now in configuration mode.
To save your settings and exit Configuration Mode, press the
Enable/Disable button.
Atomizing Air
(Classic)
Total Flow
(Smart Flow)
Setting/Display
Select Charge
Mode Settings
KV/A Setting/Display
KV/uA Selection
Control
Smart Flow Mode
Indicator
Flow-Rate Air
(Classic)
Powder Flow Rate
(Smart Flow)
Setting/Display
Enable/Disable
Trigger LED
Figure 3-16 Controller Interface